  1. Hello again. It turns out that SkyWatcher engineers noticed the problem, which is that the recent firmware version allows to change the serial connection baudrate on-the-fly. At start SynScan app requests the change to a higher baud rate for the RA axis, but not for the DEC axis, and then it "talks" to both axis at the higher baud rate, with DEC axis being unable to understand. The SynScan app published today (version 2.3.8) solves the issue, and should work with latest firmwares for all mounts. Regards.
  2. Hello. I'm having just the exact same issue but with an EQ8 PRO. Thanks to your EQ6 download link I have guessed that for the EQ8 the 2.11 file is: https://inter-static.skywatcher.com/downloads/eq8_motor_controller_v0211.zip But... how could we know from Sky-watcher what the problem with 2.15 is? Anyone knows something? Why do they keep 2.15 versions on their web without knowing that they break the SynScan app communication? Regards.
×
×